Subject: Re: mysterious TV problem -- source?
Message-ID: <1993Apr16.135837.28099@uhura.neoucom.edu>
Organization: Northeastern Ohio Universities College of Medicine
References: <9304151511.AA06281@deepthought.cs.utexas.edu>
Date: Fri, 16 Apr 1993 13:58:37 GMT
Lines: 19

If the set is direct line powered, try checking the [likely to be
there] hybrid regulator module down stream from the 170 volt
supply.  Several sets I've looked at use a 135 volt regulator.  The
regulators have a tendency to short out, making the safety circuits
shut down the EHT supply section.

Try putting the set on a Variac or adjustable transformer and lower
the AC input voltage to the set to about 90 volts.  If the set
operates nromally, then you know you've got a shorted regulator.

There are myriad other areas for problems, but I've seen the one
above several times.  Also, if the set uses one, the trippler
module may be shot; that's fairly common.


-- 
Bill Mayhew      NEOUCOM Computer Services Department
Rootstown, OH  44272-9995  USA    phone: 216-325-2511
wtm@uhura.neoucom.edu (140.220.1.1)    146.580: N8WED